Quick answer: Energy-efficient rooflights

What U-value should a rooflight have in Wales?

READ:
5 min read
AREA:
Swansea and 30 miles

Short answer

For a rooflight in an existing Welsh home, Approved Document L (Wales) says the U-value should be no worse than 2.2 W/m²K. A roof window has a tighter figure, 1.4 W/m²K or Window Energy Rating band B. The lower the number, the less heat passes through the glass. Which one applies depends on how the unit sits in the roof.

Free survey / fixed written quote / Building Control notification handled / 10-year workmanship guarantee

Two products, two numbers

Wales gives a rooflight and a roof window different limits, and the two are easy to swap by mistake. The difference comes from the way each is built into the roof.

Approved Document L describes a rooflight as a glazed unit set out of plane with the roof surface, on a kerb or upstand. The same entry notes that people also call it a skylight, so the two words mean one product here. A roof window is one installed in the same orientation as the surrounding roof, and in plane with it. A flat-roof dome on a kerb is the first kind, and a window lying in a pitched slope is the second.

Approved Document L (Wales), new or replacement units in an existing home.
ProductHow it sitsLimit
Roof windowIn plane with the roof slope1.4 W/m²K or WER band B
RooflightOn a kerb or upstand, out of plane2.2 W/m²K

What the figure covers

These numbers are guidance. A new or replacement roof window should meet 1.4, and a rooflight should meet 2.2. They are the same figures that apply in England, though the Welsh document numbers its tables differently, so a table reference copied from an English page will point at the wrong thing.

For a rooflight, the calculation looks at the unit as a whole. The U-value counts the full surface of the unit, which is often larger than the opening it covers in the roof. A kerb that comes sold with the rooflight in one piece sits inside the same 2.2 figure. When someone quotes you a number, find out whether it describes the glass alone or the complete unit, because the two are not the same thing.

Terms you will meet

U-value
How much heat passes through a material; a lower figure is better.
W/m²K
The unit a U-value is given in.
WER
Window Energy Rating; band B is the alternative to 1.4 for a roof window.
Kerb
The raised frame, also called an upstand, that a rooflight sits on.

Lanterns, and older houses

The document does not name roof lanterns when it defines a rooflight. So we do not apply the 2.2 figure to a lantern by name. A lantern on an existing flat roof is a case for the survey, and so is one in a new extension, where we confirm the approach with the council.

Older and historic houses get a little leeway. Where a replacement roof window on a home of architectural or historic interest cannot reach 1.4, the document allows a fallback of 1.2 W/m²K measured at the centre of the pane, or low-emissivity secondary glazing. The document offers nothing equivalent for rooflights, which stay at 2.2 whatever the age of the house.

Checking a product against the limit

Start by asking which of the two a unit counts as. Then ask for its declared figure, and ask whether that figure covers the glazing, the frame and, for a rooflight, its kerb. A roof window can be shown to comply by either route: a U-value of 1.4 or better, or a WER in band B.

The glazing makes the difference. Double or triple glazing and the coatings on the glass all feed into the rating. The question of whether better glazing costs more has its own answer in does an energy-efficient rooflight cost more. Our guide to rooflight U-values explained shows how the number is built up, and the Welsh Government's Approved Document L page carries the document itself.

Where the work is checked

Under the Building Regulations a rooflight or roof window is a controlled fitting, which makes installing one building work. A new rooflight will generally need Building Regulations approval, and where the work is notifiable, we handle the Building Regulations notification with local authority building control or a registered building control approver.

Planning is separate. In a conservation area, a National Park, the Gower AONB or a World Heritage Site, a new rooflight in a roof slope needs planning permission. Our skylight planning permission guide covers the rest. To have your own roof looked at, call 01792 929062 or book a free survey.

Questions we are asked

Is the Welsh limit different from the English one?

The figures match, at 1.4 for a roof window and 2.2 for a rooflight. The tables carrying them are numbered differently in the Welsh document, which is the part that catches people out.

What does a lower U-value actually mean?

Less heat passes through the unit. The guidance asks only that a rooflight be no worse than 2.2, so any unit with a lower figure leaves you more margin.

Do the limits change in 2027?

The next Welsh edition of the document starts on 4 March 2027, and it keeps the same window, roof window and rooflight figures.

Does a flat-roof dome count as a rooflight?

The document defines a rooflight by how it sits, as a glazed unit on a kerb or upstand and out of plane with the roof. A dome on a flat roof fits that description, so the 2.2 figure is the one that applies to it.

Why does a roof window have a tighter limit than a rooflight?

The document does not give a reason. It simply sets 1.4 for roof windows and 2.2 for rooflights in its table of limits, and treats them as separate products.

Who confirms my rooflight meets the rules?

The notification goes to local authority building control or a registered building control approver. We make it on your behalf when the job calls for one.